Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
Eur Spine J ; 25(7): 2311-6, 2016 07.
Artigo em Inglês | MEDLINE | ID: mdl-26869079

RESUMO

PURPOSE: The Cervical Spine Research Society Europe (CSRS-E) actively promotes scientific activities, the annual meeting being the most evident of them. The publication rate of oral and poster presentations at the annual meeting could be a measure for the success of the promotional activities. The publication rates of abstracts presented at the annual European meetings of the CSRS are unknown. The quality of the abstracts presented at a conference is reflected by the publication rate. A high publication rate is usually interpreted as representative of high scientific value of the conference. METHODS: Poster and podium presentations from the 2007 to 2012 annual meetings were identified. Pubmed was used to search for the abstract title and/or the combination of authors to verify whether the data were published in a peer-reviewed journal. Abstracts were considered published if the data presented at the meeting were identical to that in the publication. The journals in which the data were published were identified, as well as the origin of the research centre. RESULTS: From 2007 to 2012 826 abstracts were featured at the CSRS Europe annual meetings. There were 236 podium presentations and 590 poster presentations. 42 % of the podium presentations resulted in a publication, and 28 % of the poster presentations led to a publication. Overall, 32 % of accepted abstracts effectuated a publication in a peer-reviewed scientific journal. Abstracts from European research groups had a publication rate of 29 % compared to 34 % for abstracts from non-European research groups. Spine, European Spine Journal, Journal of Spinal Disorders and Techniques and J Neurosurgery Spine were the most common publication journals for the abstracts. The mean impact factor of the journals in which was published was 2.2. CONCLUSION: 42 % of the abstracts that were accepted for podium presentation at the CSRS Europe resulted in a publication in peer-reviewed MEDLINE indexed journals. Publication rates are at the high end of the publication rate spectrum of abstracts accepted for European scientific meetings.


Assuntos
Bibliometria , Editoração/estatística & dados numéricos , Doenças da Coluna Vertebral , Indexação e Redação de Resumos , Vértebras Cervicais , Europa (Continente) , Humanos , Fator de Impacto de Revistas , Revisão por Pares , Publicações Periódicas como Assunto/estatística & dados numéricos , Sociedades Médicas
2.
An. sist. sanit. Navar ; 38(3): 417-424, sept.-dic. 2015. tab, ilus, graf
Artigo em Espanhol | IBECS | ID: ibc-147335

RESUMO

Fundamento: Las imágenes obtenidas mediante estudios con TC pueden ser alteradas por la presencia de artefactos metálicos, induciendo en ocasiones a malinterpretación en la correcta ubicación de los tornillos pediculares en columna lumbar. El objetivo de este trabajo es desarrollar un protocolo de atenuación del artefacto metálico con el propósito de reducir el artefacto generado por los tornillos pediculares de titanio en aquellos pacientes a los que se ha requerido instrumentación lumbar, permitiendo a los cirujanos de columna realizar un diagnóstico preciso de la ubicación del tornillo pedicular instrumentado. Material y métodos: En la primera parte del trabajo se realizó un estudio observacional, analítico, longitudinal y retrospectivo en 23 pacientes (103 tornillos pediculares) a los que se requirió artrodesis lumbar por patología degenerativa. En el postoperatorio se les realizó un estudio con TC secuencial evaluando la sobredimensión generada por el artefacto del tornillo, aplicando un protocolo estándar de obtención de imágenes. En la segunda parte del estudio se diseñó un estudio observacional, analítico, longitudinal y prospectivo empleando un equipo de TCMC de 64 coronas aplicando un protocolo específico de adquisición de imagen sobre 18 pacientes (104 tornillos pediculares) intervenidos mediante artrodesis lumbar. Resultados: En la primera parte del estudio el artefacto medio a ambos lados del tornillo que se genera tras el estudio de TC es de 1,045 mm (DE: 0,45). En el grupo en el que se aplica el protocolo de atenuación del artefacto tras la TCMC la sobredimensión fue de 0,005 en la porción proximal del tornillo y de 0,025 en la parte distal del tornillo. Conclusiones: Los resultados obtenidos sugieren que tras la aplicación del protocolo de atenuación del artefacto en equipo de TCMC de 64 coronas el artefacto es reducido a unas dimensiones similares a la dimensión real del tornillo pedicular(AU)


Background: In postoperative patients with metallic implants, CT scans can become less effective due to metal-related artifacts. The purpose of our study was to evaluate the effectiveness of a specific metal artifact reduction image protocol, in order to reduce the metal artifact caused by titanium pedicular screws in patients undergoing lumbar pathology by lumbar fusion. This enables surgeons to make an accurate diagnosis of the exact placement of inserted pedicle screws, making this the preferred image modality for assessing screw position after surgery. Methods: In the first part of the study, CT scans were performed on 23 patients (103 titanium alloy pedicle screws) undergoing a lumbar instrumented fusion for treatment for degenerative disease with a standard image acquisition protocol evaluating the possible overdimension caused by the artifact. In the second part, a prospective study was performed using 64-slice multidetector-row computed tomography (MDCT) on 18 patients (104 titanium alloy pedicle screws) undergoing a lumbar instrumented fusion using a specific image acquisition protocol. Results: Our results show that in the sequential CT scan group, mean overdimension (on each side) due to brightness was 1.045 mm (SD 0.45). In the 64-slice multichannel CT group, mean overdimension (on each side) due to brightness was 0.005 mm at the proximal part of the screw and 0.025 mm at the distal part of the screw. Conclusions: The use of a specific metal artifact reduction image protocol in MDCT produces a minimal artifact following lumbar fusion with pedicle screws (AU)


Assuntos
Humanos , Masculino , Feminino , Dor Lombar/metabolismo , Dor Lombar/patologia , Protocolos Clínicos/classificação , Tomografia Computadorizada por Raios X/instrumentação , Tomografia Computadorizada por Raios X/métodos , Artrodese/métodos , Artrodese/normas , Estudos Retrospectivos , Artefatos , Dor Lombar/complicações , Dor Lombar/diagnóstico , Protocolos Clínicos/normas , Tomografia Computadorizada por Raios X/normas , Tomografia Computadorizada por Raios X , Artrodese/efeitos adversos , Artrodese , Estudo Observacional
3.
An Sist Sanit Navar ; 38(3): 417-24, 2015.
Artigo em Espanhol | MEDLINE | ID: mdl-26786369

RESUMO

BACKGROUND: In postoperative patients with metallic implants, CT scans can become less effective due to metal-related arti-facts. The purpose of our study was to evaluate the effectiveness of a specific metal artifact reduction image protocol, in order to reduce the metal artifact caused by titanium pedicular screws in patients undergoing lumbar pathology by lumbar fusion. This enables surgeons to make an accurate diagnosis of the exact placement of inserted pedicle screws, making this the preferred image modality for assessing screw position after surgery. METHODS: In the first part of the study, CT scans were performed on 23 patients (103 titanium alloy pedicle screws) undergoing a lumbar instrumented fusion for treatment for degenerative disease with a standard image acquisition protocol evaluating the possible overdimension caused by the artifact. In the second part, a prospective study was performed using 64-slice multide-tector-row computed tomography (MDCT) on 18 patients (104 titanium alloy pedicle screws) undergoing a lumbar instrumented fusion using a specific image acquisition protocol. RESULTS: Our results show that in the sequential CT scan group, mean overdimension (on each side) due to brightness was 1.045 mm (SD 0.45). In the 64-slice multichannel CT group, mean overdimension (on each side) due to brightness was 0.005 mm at the proximal part of the screw and 0.025 mm at the distal part of the screw.


Assuntos
Artefatos , Tomografia Computadorizada Multidetectores , Fusão Vertebral , Parafusos Ósseos , Humanos , Vértebras Lombares , Estudos Prospectivos , Próteses e Implantes
4.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 55(3): 175-180, mayo-jun. 2011.
Artigo em Espanhol | IBECS | ID: ibc-129074

RESUMO

Introducción. En la práctica clínica observamos con cierta frecuencia una prominencia esternoclavicular dolorosa, deformidad que constituye el principal signo de dos entidades con baja incidencia, aunque bien definidas: la hiperostosis esterno-costo-clavicular (HECC) y la osificación inter-esterno-costo-clavicular (OIECC). El diagnóstico diferencial de estas afecciones debe incluir la artrosis esterno-clavicular, la enfermedad de Paget, la osteitis condensante, la osteomielitis, la pustulosis, la enfermedad de Friederich, el síndrome de Tietze y el osteoma osteoide. Esto es especialmente importante en los casos en los que la afectación sea unilateral. Material y método. Presentamos una serie de nueve pacientes cuyo motivo de consulta fue una prominencia esterno-costo-clavicular, compatible con HECC u OIECC. El motivo de consulta en la mayoría de los pacientes fue el descartar la presencia de un tumor en esa localización. Resultados. Los estudios radiológicos mostraron un aumento variable tanto de la densidad como de la masa ósea, así como diferentes intensidades de afectación de la articulación esterno-costo-clavicular. Discusión. Descartado un tumor y con un diagnóstico concreto de la causa de la prominencia, generalmente, se considera suficiente con el tratamiento antiinflamatorio en la mayoría de los pacientes. En la práctica clínica parece irrelevante la diferenciación entre HECC y OIECC, ya que el tratamiento y el pronóstico de ambas afecciones son superponibles. La biopsia de la articulación y los procedimientos diagnósticos invasivos pueden ser innecesarios(AU)


Introduction. In clinical practice, we see quite often painful sterno-clavicular prominence, deformity, which is the hallmark of two entities with a low incidence, although well defined hyperostosis cost sterno-clavicular (HECC) and ossification cost inter-sterno-clavicular (OIECC). The differential diagnosis of these conditions, you must include sterno-clavicular arthritis, Paget's disease, condensing osteitis, osteomyelitis, pustulosis, Friederich's disease, Tietze's syndrome and osteoid osteoma. This is especially important in cases where the involvement is unilateral. Material and methods. We present a series of nine patients complaining of a painful sterno- clavicular prominence, compatible with HECC or OIECC. The reason for consultation in most patients was rule out the presence of a tumor in that location. Results. Image studies showed a variable increase both the density and bone mass as well as different intensities of joint involvement sterno-clavicular cost. Conclusion. Ruled out a tumor and a specific diagnosis of these, you do not need aggressive treatment, is generally considered sufficient anti-inflammatory treatment in most patients. In clinical practice, it is irrelevant and OIECC HECC differentiation, since treatment and prognosis of both conditions are similar. The biopsy of the joint and aggressive diagnostic procedures may be unnecessary (AU)


Assuntos
Humanos , Masculino , Feminino , Articulação Esternoclavicular/anormalidades , Hiperostose Esternocostoclavicular/complicações , Hiperostose Esternocostoclavicular/diagnóstico , Osteogênese/fisiologia , Osteoartrite/complicações , Osteoma Osteoide/complicações , Articulação Esternoclavicular/patologia , Articulação Esternoclavicular , Hiperostose Esternocostoclavicular/patologia , Hiperostose Esternocostoclavicular/fisiopatologia , Hiperostose Esternocostoclavicular , Diagnóstico Diferencial , Osteíte Deformante/complicações , Psoríase/complicações , Síndrome de Tietze/complicações
5.
MAPFRE med ; 13(4): 241-247, oct. 2002. ilus, tab
Artigo em Es | IBECS | ID: ibc-17475

RESUMO

Introducción: La finalidad de este estudio prospectivo es analizar los resultados de un método ideado para evitar los errores durante la colocación de los tornillos en raquis lumbosacro, el cual está basado en una valoración preoperatoria de la morfología vertebral y una actuación ordenada en quirófano. Material y métodos: Se realizó una TAC preoperatoria con cortes a la altura de los pedículos para evaluar la morfometría pedicular y la morfología vertebral y preparar un plan preoperatorio. La colocación de los tornillos pediculares fue realizada por un cirujano experiencia y un residente, siguiendo los siguientes pasos utilizando escopia con Rx: durante la introducción del tornillo proyección AP perfecta, si pasa el borde interno del pedículo la proyección lateral nos muestra la situación de la punta del tornillo. La proyección lateral evalúa la ruptura de la cortical craneo-caudal pedicular. La proyección oblicua y proyección de desfiladero pélvico evalúan la ruptura de la cortical lateral pedicular y anterior del cuerpo vertebral. Se realizó una TAC postoperatoria con cortes a la altura de los tornillos para evaluar la posición exacta. Resultados: 21 pacientes operados con nuestra instrumentación (CUN) para artrodesis lumbosacra. 103 tornillos introducidos: 74 por el cirujano y 29 por el residente. Seis rupturas de cortical (5,8 per cent): tres mediales, dos anteriores y una lateral, ninguna de ellas por más de 2 mm y ninguna lesión radicular. Tiempo de radiación: 40 segundos por tornillo. Conclusiones: Basados en el bajo número y repercusión de los 'tornillos mal colocados', la simplicidad del método de introducción, la fácil reproductibilidad del método por cirujanos no experimentados y el bajo tiempo de radiación, concluimos que nuestro método proporciona un muy aceptable bajo número de errores en los tornillos pediculares colocados (AU)


Assuntos
Humanos , Erros Médicos/prevenção & controle , Coluna Vertebral/cirurgia , Plexo Lombossacral/cirurgia , Parafusos Ósseos , Lesões nas Costas/cirurgia , Estudos Prospectivos , Resultado do Tratamento , Tomografia Computadorizada por Raios X
6.
Rev. ortop. traumatol. (Madr., Ed. impr.) ; 46(2): 158-164, abr. 2002. tab, ilus
Artigo em Es | IBECS | ID: ibc-18552

RESUMO

La morfología vertebral y pedicular condiciona el tamaño de los implantes pediculares tanto en anchura como en longitud y orientación del tornillo en el momento de su introducción. Se procedió a medir la anchura pedicular cortical y endostal, la angulación de los pedículos y la longitud del cuerpo vertebral, así como a valorar la forma del cuerpo vertebral en 45 pacientes españoles estudiados mediante TAC. Para este estudio los cortes pasaban por el pedículo de L3 en 8 vértebras, de L4 en 37 vértebras, de L5 en 44 vértebras L5 y de S1 en 40 vértebras. Se compararon estadísticamente los valores obtenidos entre varones y mujeres. La anchura cortical aumentaba desde L3 con 8,7 mm hasta S1 con 21,3 mm, la anchura pedicular endostal desde 6,2 mm en L3 hasta 17,4 mm en S1, la angulación pedicular de 10,3° en L3 hasta 28,2° en S1 y la longitud del cuerpo vertebral desde 33,0 mm en L3 a 35,4 mm en S1. Las vértebras lumbares desde L3 admitían, en la mayoría de los casos, tornillos pediculares de 5,5 mm. Por la forma y tamaño vertebral, en L5 y S1 se debe introducir los tornillos pediculares de modo convergente si se utilizan tornillos de más de 40 mm de longitud para evitar traspasar la pared anterior del cuerpo vertebral. (AU)


Assuntos
Feminino , Masculino , Humanos , Região Lombossacral/anatomia & histologia , Vértebras Lombares/anatomia & histologia , Parafusos Ósseos , Tomografia Computadorizada por Raios X/métodos , Região Lombossacral , Vértebras Lombares
7.
Rev. ortop. traumatol. (Madr., Ed. impr.) ; 45(2): 106-113, abr. 2001.
Artigo em Es | IBECS | ID: ibc-398

RESUMO

Estudios previos sugieren una alta incidencia de errores en la introducción de los tornillos pediculares. La frecuencia de tales errores detectada por TAC ha resultado ser mayor que la detectada por las radiografías simples. El objetivo de este estudio es evaluar la precisión de la radiografía simple versus la TAC para el diagnóstico de errores en la colocación de tornillos, su fiabilidad intraobservador e interobservadores y para proveer datos cuantitativos y cualitativos de la incidencia de malposiciones y complicaciones relacionadas. Métodos: En 38 pacientes se realizó una instrumentación en columna lumbosacra con tornillos pediculares de titanio insertados en dirección recta sagital (232 tornillos). En todos los pacientes se realizaron radiografías en proyección anteroposterior y lateral, y TAC en el plano en el cual los tornillos fueron introducidos. Un observador evaluó las TAC. Tres observadores evaluaron independientemente las radiografías, considerando que los tornillos estaban mal colocados cuando habían penetrado cualquier cortical vertebral o pedicular. Resultados: La concordancia interobservador e intraobservador fue regular a moderada para la valoración radiográfica de la situación del tornillo pedicular. La TAC versus radiografía mostró una concordancia regular a moderada. La TAC demostró 28 por ciento de tornillos que penetraban alguna cortical, 2,6 por ciento de los tornillos perforaron la cortical medial pero ninguno entró completamente en el canal. En un paciente se presentó lesión radicular incompleta (2,6 por ciento de pacientes; 0,3 por ciento de tornillos). Conclusiones: La radiología simple en dos proyecciones no es un método preciso para la valoración de la posición de los tornillos pediculares. En nuestras series se ha observado una alta incidencia de penetraciones corticales, más frecuentes en la corteza lateral y anterior, sin embargo, la incidencia de complicaciones neurológicas fue baja (AU)


Assuntos
Tomografia Computadorizada por Raios X , Parafusos Ósseos , Região Lombossacral/patologia
9.
Rev. Ecuat. cancerol ; (2): 107-11, dic. 1997. ilus
Artigo em Espanhol | LILACS | ID: lil-235698

RESUMO

Revisa a 60 pacientes con tumores malignos a nivel de columna vertebral que fueron tratados entre 1984 a 1990 en la Clínica Universitaria de Navarra. El grupo estudiado (20 pacientes) consistió en 14 varones y 6 mujeres, de 7 a 72 años (promedio:38 años). En 12 pacientes el tumor fue localizado a nivel de la región lumbar, 6 a nivel de columna dorsal, y en un caso a nivel sacro. En todos los casos fueron tratados con radioterapia intraoperatoria mediante el uso de acelerador lineal. La energía usada varía entre los 6 y 20 Mev. La dosis total recibida varía entre los 10 y 20 Grays. Adicionalmente los pacientes recibieron radioterapia externa. No se observaron complicaciones relacionadas con la radioterapia intraoperatoria. En conclusión: La RIO es una técnica factible para el tratamiento de tumores óseos. La toxicidad de RIO es mínima. Es una alternativa para el control local del tumor, en lugares de difícil acceso para tratamiento radical. La RIO es parte del tratamiento multidisplinario en esta patología.


Assuntos
Humanos , Neoplasias , Radioterapia , Sarcoma , Coluna Vertebral , Pacientes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...